常规力学试验加荷速度一览表试验项目加荷速度备注水泥胶砂抗压试验2.4kN/s±0.2kN/s/水泥混凝土圆柱体劈裂抗拉强度试验(假定L=200mm,D=100mm)0.17kN/s~0.49kN/s<C30(<4.5MPa)0.49kN/s~0.84kN/s≥C30且<C60(≥4.5MPa且<5.5MPa)0.84kN/s~1.09kN/s>C60岩石单轴抗压强度试验1.50kN/s ~2.50kN/s边长为50mm2.40kN/s~4.90kN/s边长为70mm水泥混凝土立方体抗压强度6.75kN/s~11.250kN/s<C30(0.3~0.5MPa/s)11.25kN/s~18.0kN/s≥C30且<C60(0.5~0.8MPa/s)18.0kN/s~22.5kN/s>C60(0.8~1.0MPa/s)水泥混凝土抗弯拉试件断块抗压强度试验6.75kN/s~11.250kN/s<C30(0.3~0.5MPa/s)11.25kN/s~18.0kN/s≥C30且<C60(0.5~0.8MPa/s)18.0kN/s~22.5kN/s>C60(0.8~1.0MPa/s)水泥混凝土圆柱体轴心抗压强度试验6.75kN/s~11.250kN/s<C30(0.3~0.5MPa/s)11.25kN/s~18.0kN/s≥C30且<C60(0.5~0.8MPa/s)18.0kN/s~22.5kN/s>C60(0.8~1.0MPa/s)水泥混凝土棱柱体抗压弹性模量试验4.5kN/s~22.5kN/s0.6MPa/s±0.4MPa/s水泥混凝土圆柱体抗压弹性模量试验假设(假定d=150mm)3.53kN/s~17.67kN/s0.6MPa/s±0.4MPa/s水泥混凝土棱柱体抗压强度4.5kN/s~22.5kN/s0.6MPa/s±0.4MPa/s粗集料压碎值指标40kN/min至压力400kN止混凝土芯样抗压强度试验(假定d=100mm)2.36kN/s~3.93kN/s<C30(0.3~0.5MPa/s)3.93kN/s~6.28kN/s≥C30且<C60(0.5~0.8MPa/s)6.28kN/s~7.85kN/s>C60(0.8~1.0MPa/s)桩基芯样抗压强度试验(假定d=100mm)2.36kN/s~3.93kN/s<C30(0.3~0.5MPa/s)3.93kN/s~6.28kN/s≥C30且<C60(0.5~0.8MPa/s)6.28kN/s~7.85kN/s>C60(0.8~1.0MPa/s)预应力混凝土用钢绞线试验10mm/min屈服前75mm/min屈服后水泥混凝土抗弯拉强度试验0.15kN/s~0.375kN/s5.0MPa0.375kN/s~0.6kN/s4.5MPa(水运)水泥砂浆抗压试验//(公路)水泥砂浆立方体抗压强度试验0.5kN/s~1.5kN/s小于或等5.0MPa下限为宜大于5.0MPa上限为宜(建工)建筑砂浆抗压强度试验//岩石芯样抗压强度试验0.98kN/s~1.96kN/sD=50mm无侧限抗压强度试验1mm/min/水泥土桩芯样抗压强度试验0.59kN/s~0.98kN/s/钢筋机械连接接头力学性能试验0.05Lc/minD≤20mm0.05Lc/minD>20mm钢材力学性能试验最小最大中值钢筋直径(mm)钢筋截面面积(mm2)0.171.700.93628.270.303.021.66850.270.474.712.591078.540.686.793.7312113.10.929.245.0814153.91.2112.066.6416201.11.5315.278.4018254.51.8818.8510.3720314.22.2822.8112.5422380.12.9529.4516.2025490.93.6936.9520.3228615.84.8348.2526.5432804.26.1161.0733.593610187.5475.4041.4740125711.78117.8164.80501963钢筋焊接接头力学性能试验0.280.850.57628.270.501.511.01850.270.792.361.571078.541.133.392.2612113.11.544.623.0814153.92.016.034.0216201.12.547.635.0918254.53.149.426.2820314.23.8011.407.6022380.14.9114.739.8225490.96.1618.4712.3228615.88.0424.1316.0832804.210.1830.5420.3636101812.5737.7025.1340125719.6358.9039.27501963